Ultrasound Epidural, Lumbar Puncture and Spinal Anaesthesia Model – Light

Product no. HAN497
Manufacturer code. 61002

The Advanced Epidural & Lumbar Puncture trainer is suitable for use in Clinical Skills Centres, where both early postgraduate medical and anaesthesia specialisms are taught. Trainees are at a more advanced stage of training, and great realism and the ability to practice on a variety of patients is essential for continued learning.

Read additional information

£2,335.50

£2,802.60
with VAT
Or
£2,335.50
without VAT
Expected delivery:
4 Working days

30 Day Account
Pay via invoice for your order
Accepting NHS POs
Send your purchase order direct
Free Quotes
Receive an official quote for your order
VAT Exemption
Purchase with 0% VAT for a disability or charity

Additional information

Ultrasound Epidural, Lumbar Puncture and Spinal Anaesthesia Model - Light

The Advanced Epidural & Lumbar Puncture trainer is suitable for use in Clinical Skills Centres, where both early postgraduate medical and anaesthesia specialisms are taught. Trainees are at a more advanced stage of training, and great realism and the ability to practice on a variety of patients is essential for continued learning.

What are the latest features that support training in administering lumbar punctures?

In training sessions, medical students will get a true-to-life experience, including:

  • A distinctive “pop” when puncturing the Dura (using the standard Dura) during a lumbar puncture procedure or more subtle feedback when using the advanced Dura.
  • Measurable cerebrospinal fluid (CSF) pressure, model can present realistic pressure between 5 to 25 cmH2O.
  • Realistic flow of fluid from the water reservoir, increasing the volume of water will increase the flow rate allowing for quicker training.

What are the latest features that support training in epidural procedures?

  • Ligamentum flavum and interspinous ligaments allow for more realistic haptic feedback and practice of loss of resistance techniques during needle insertion.
  • 6mm epidural space between the insert and the dura enables practice threading an epidural catheter and administering fluids.
  • Softer silicone on either side of the spine offers greater realism and the paramedian approach is easier to perform.
  • Four epidural inserts are supplied with this model; the advanced insert has a steeper angle with a reduced epidural space, allowing practice of more difficult injections.
  • The advanced model comes with three fat pads that can be inserted behind the Skin Pad. Used individually or in combination, they can simulate patients with different amounts of body fat, allowing trainees to practice varying difficulties of injection.

To ensure that ongoing costs remain low, this trainer comes with two LP Tissue Inserts, two standard Epidural, and two advanced Epidural Inserts. This makes for a more cost-effective way to train large numbers of students. Inserts are easily interchangeable and offer a variety of training scenarios.

Augmented Reality is now part of the Lumbar Puncture range

The new ART Mats combine real-world MRI and CT scan data, with the skills of talented medical artists and digital creators, to bring the internal anatomy of our trainers to life.

Within the L&T ART app’s digital environment, you can move around your task trainer and view various overlays, including: the musculature, organs and vessels, and skeletal structure. The interface allows you to move seamlessly between the layers, as well as view their cross-sections.

Students are also able to view digital procedures in the AR environment to see how the procedure is done, and its impact on the patient’s anatomy.

Overview
  • NEW: Augmented Reality capabilities with the ART Mat
  • Simulator gives a distinctive “pop” feeling when puncturing the dura during a lumbar puncture procedure
  • Durable lumbar tissue insert and duras are longer lasting, increasing lifespan and keeping ongoing costs down
Realism
  • Needle insertion possible between vertebrae
  • Ability to feel when the dura is punctured during lumbar puncture
  • Realistic rate of cerebrospinal fluid (CSF) can be simulated
  • Fat pads can be inserted to vary the patient form
Versatility
  • All epidural and lumbar puncture inserts are compatible with the common base
  • Skin and duras can be rotated to extend their lifespan and ensure cost-effective training
  • The stand provided allows for training in left lateral and sitting positions
Cleaning
  • Drain all fluid from the product when not in use
  • Clean lumbar puncture trainer with a damp cloth, using warm water and mild detergent
  • Allow trainer to completely dry before storing
Safety
  • This product is latex-free
Simulated Patient
  • This product can be used with a simulated patient to develop communication skills
Anatomy
  • Palpable sacrum
  • Iliac crests
  • Lumbar vertebrae between L2 and L5 with spinous processes
  • Ligamentum flavum
  • Interspinous Ligament
Skills Gained
  • Identifying the iliac crests
  • Administering local anaesthetic injections
  • Administering therapeutic treatments, e.g. antibiotics or chemotherapy medication
  • Performing diagnostic lumbar punctures
  • Collection and measurement of cerebrospinal fluid
  • Performing procedures in a sitting and left lateral position
  • Administration of an epidural

Supplying Medical Equipment to the NHS for over 20 years

With excellent service and after sale support. Please dont hesitate to contact us.