Sale!

Drive Devilbiss Apollo II Dynamic Replacement Mattress System

Drive Devilbiss
Product no. HDA695
Manufacturer code. DYN/DIG/APOLLO/2

Drive DeVilbiss Apollo II Dynamic Replacement Mattress System for high risk pressure area care. Featuring alternating and constant low pressure therapy modes, automatic pressure control, Dartex® vapour permeable cover, CPR release, transport mode, and a 200kg user weight capacity.

Read additional information

Original price was: £1,394.39.Current price is: £1,062.53.

was £1,673.27
£1,275.04
with VAT
Or
£1,062.53
without VAT
Expected delivery:
5 Working days

30 Day Account
Pay via invoice for your order
Accepting NHS POs
Send your purchase order direct
Free Quotes
Receive an official quote for your order
VAT Exemption
Purchase with 0% VAT for a disability or charity

Additional information

Drive DeVilbiss Apollo II Dynamic Replacement Mattress System

The Drive DeVilbiss Apollo II Dynamic Replacement Mattress System is a clinically advanced pressure area care surface designed for use in hospital, residential care, and homecare environments. Developed to support enhanced patient care and outcomes, the Apollo II offers dual therapy modes for patients considered at high risk of pressure damage.

The system provides Alternating Therapy Mode, delivering pressure relief over a 10 minute cycle in a 1-in-2 AB pattern, as well as Constant Low Pressure (CLP) Therapy Mode, which creates a static low pressure surface to support patient immersion and pressure redistribution.

The Apollo II pump automatically detects which compatible dynamic surface has been connected and adjusts the pressure setting accordingly. Comfort settings can also be adjusted from soft to firm, helping clinicians tailor support to the individual user. The system includes audible and visual alerts, auto lockout, mute function, accessible rear filter, and integral hanging hooks for mounting the pump to the bed footboard.

The mattress includes 20 cells, made up of 3 static head cells and 17 alternating cells. The individual cell “air on air” construction helps reduce the risk of bottoming out, while the CPR dial at the foot end allows rapid deflation in an emergency. Transport Mode can be used for up to 8 hours during power outages or patient transport by sealing the umbilical cord connector with the transport cap.

The Dartex® multi-stretch cover is water resistant and vapour permeable, with an anti-fungal agent encapsulated in the cover to help control microbial deterioration. A white inner substrate helps identify signs of cover damage or strike-through, while the 360° zip, welded seams, and waterfall flap help reduce the risk of fluid ingress. The mattress also includes 8 securing straps with D rings and a cable management system on the bottom cover.

Key Features
  • Dynamic replacement mattress system for pressure area care
  • Suitable for patients at high risk of pressure damage
  • Designed for hospital, residential care, and homecare environments
  • Dual therapy modes: Alternating Therapy and Constant Low Pressure
  • 10 minute cycle time with 1-in-2 AB alternating pattern
  • Max Inflate Mode inflates all cells for 20 minutes during patient movement or repositioning
  • Automatic Pressure Control System monitors and maintains mattress pressure
  • Adjustable comfort control settings from 1 soft to 5 firm, default setting 3
  • Pump automatically detects compatible connected dynamic surface
  • Audible and visual alerts for low pressure or power failure
  • Auto lockout after 2 minutes of inactivity to prevent accidental setting changes
  • Mute button allows acknowledged alerts to be silenced while investigated
  • Accessible rear filter for ease of maintenance
  • Integral hanging hooks for suspending pump from the bed footboard
  • 20 cell mattress construction: 3 static head cells and 17 alternating cells
  • “Air on air” cell construction helps reduce risk of bottoming out
  • CPR dial at foot end allows rapid emergency deflation
  • Transport Mode supports pressure redistribution for up to 8 hours
  • Dartex® multi-stretch, water resistant, vapour permeable top cover
  • Anti-fungal agent encapsulated in the cover to help control microbial deterioration
  • White inner substrate helps identify cover damage and strike-through
  • 360° zip, welded seams, and waterfall flap help reduce fluid ingress
  • Bottom cover includes cable management system to help reduce trip hazards
  • 8 securing straps with D rings for attachment to compatible bed frames
  • Compliant with EN 60601-1, EN 60601-1-2, and EN 60601-1-11
Specification
  • SKU: DYN/DIG/APOLLO/2
  • Label: Apollo II Dynamic Replacement Mattress System
  • Risk factor: At high risk
  • User weight capacity: 200kg / 31.5st
  • Mattress length: 200cm
  • Mattress width: 88cm
  • Mattress depth: 20cm
  • Product weight: 12.3kg total, including 2.3kg pump and 10kg mattress
  • Pump dimensions: 20.5cm x 28cm x 11.5cm
  • Cell cycle time: 10 minutes
  • Cell cycle type: 1-in-2 AB pattern
  • Cover material: Dartex® multi-stretch, water resistant, vapour permeable
  • Seams: Welded
  • Fire retardancy: BS7175: 1989
  • Barcode: 5055785718379

Supplying Medical Equipment to the NHS for over 20 years

With excellent service and after sale support. Please dont hesitate to contact us.