6%
Portable Densitometer, Cell density turbidity for 16 or 18mm tube
DEN-1B Portable Densitometer (Cell density turbidity)
The Grant bio DEN-1 and DEN-1B are a compact benchtop densitometers (suspension turbidity meter) for measuring turbidity of cell suspensions in a variety of life science applications.
Available on back-order
Additional information
DEN-1B Portable Densitometer (Cell density turbidity)
The Grant bio DEN-1 and DEN-1B are a compact benchtop densitometers (suspension turbidity meter) for measuring turbidity of cell suspensions in a variety of life science applications.
The densitometers are designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 McFarland units (DEN-1) 0.0 to >7.5 McFarland units (DEN-1B) with a small standard deviation. If required, it can deliver a wider measurement range (up to 15.00 McFarland units), but with a greater standard deviation.
- Measurement range: 0.5 to 4.0 McFarland units (DEN-1), 0.0 to >7.5 McFarland units (DEN-1B)
- Measurement time : 1 second
- Precision: ±3%
- Readings, conveniently shown in McFarland units, are clearly visible on the bright LED display
- Factory calibrated - retains calibration without power supply
- Can be user calibrated with commercial standards or cell suspensions prepared in the laboratory
- Designed for tubes with an outer diameter of 18mm. 16 mm tubes can also be accommodated by using the optional tube adaptor D-16
- Extremely compact design with small footprint and low profile - fits easily into the smallest workspace
- DEN-1b - either battery powered by 3 x AAA or via external power supply
Applications:
Life science - typical applications include determining concentration of cells (bacterial and yeast cells) in the fermentation process, detecting the susceptibility of micro-organisms to antibiotics, identifying micro-organisms with various test systems, and measuring optical density at fixed wavelength.
Specifications
Den-1 | ||
Dimensions (h x d x w) | 75 x 115 x 165mm | |
Temperature range | +4 to 40ºC | |
Light source | LED | |
Wavelength | 565 ±15Inm | |
Range (McFarland units) | 0.0 to 15.0 | |
Precision | ±3% | |
Measurement time | 1sec | |
Tube diameter - external diameter | 18mm | |
Tube diameter - with D16 adapter | 16mm | |
Sample volume | >2ml | |
Display/display resolution | LCD/0.01 McF | |
Independent power supply | 3x AA Batteries (Included) | |
External Power supply | Input AC 120-230V, 50/60Hz Output DC 12V | |
Power consumption - 230V | 0.1W (0.007A) | |
Weight | 0.7kg |