13%
Vitalograph copd-6 BT Respiratory Screener
copd-6 BT Screener
Handheld device with Bluetooth connectivity, for COPD screening
The Vitalograph copd-6™ BT identifies those at risk of COPD at the pre-symptomatic stage, screening out those whose FEV1 is normal. The screener allows early medical intervention and facilitates better clinical outcomes. Generates reports via Bluetooth connection and Vitalograph Reports software.
£240.00
Additional information
Vitalograph copd-6 BT Respiratory Screener
copd-6 BT Screener
Handheld device with Bluetooth connectivity, for COPD screening
The Vitalograph copd-6™ BT identifies those at risk of COPD at the pre-symptomatic stage, screening out those whose FEV1 is normal. The screener allows early medical intervention and facilitates better clinical outcomes. Generates reports via Bluetooth connection and Vitalograph Reports software.
Features:- Monitors COPD patients using their obstructive index – FEV1 as a percent of predicted
- Displays FEV1, FEV6, ratio, COPD classification and lung age
- Automatically sends data after each blow
- Can also send session data
- Large, easy-to-read display
- Facilitates ‘case selection’ so that spirometry can be focused on those likely to be diagnosed with COPD.
- Screens out anyone with normal FEV1 without the risk of false COPD negatives.
- Monitors COPD patients using their obstructive index which is based on FEV1 as a percent of predicted.
- Displays FEV1, FEV6, ratio and % predicted, obstructive index, COPD classification and lung age.
- Built-in quality of blow indicator.
- Displays the GOLD COPD classification (stage I – IV) to help recognise the need for a change in the patient’s management plan.
- Requires only minimal instruction for use by non-respiratory specialists.
API software developers’ kit is required for integration.
- Pouch
- Instructions for Use
- Vitalograph Reports Software
- 2 x AAA Batteries
Model: | 4000 |
Dimensions: | 109mm (length) x 63mm (width) x 42mm (height) |
Flow Detection Principal: | Stator rotor |
Accuracy: | Better than ± 3% |
Measurement Range: | 0 – 9.99 L BTPS |
Power Supply: | 2 x 1.5V AAA batteries |
Battery Life: | 3 months of use, 3 tests per day |
Quality Check: | Slow start of test (Vext>5%) or a cough detected in the first second |
FEV substituted for FEV6: | When FET < 3s and abrupt end of test |
Performance standards: | ATS/ERS 2019, ISO 23747:2015, ISO 26782:2009 |
QA/GMP standards: | EN ISO 13485, FDA 21 CFR 820, MDSAP. |
Communications: | Bluetooth |
PC Requirements for Vitalograph Reports: | Windows® 7, Windows® 8 or Windows® 10 Auto power down time: 2 minutes |