Limescale quickly forms within steam generating equipment often resulting in
restriction or possible blockage of component parts. System6 all in one
solution removes limescale (descaling) helping ensure peak operating
performance is maintained throughout the equipments working life.

Read additional information

Available on back-order

£15.54
with VAT
Or
£12.95
without VAT
Expected delivery:
7 Working days

30 Day Account
Pay via invoice for your order
NHS Orders
We supply to over 12,000 medical providers
Quote Request
Receive an official quote for your order
VAT Exemption
Purchase with 0% VAT for a disability or charity

Additional information

Limescale has also shown to be an ideal harbour for harmful bacteria.


System6 is also a high level disinfecting agent ensuring removal of bactericidal contamination from within internal operating components.


Economical

Each 1 Litre of Concentrate: Allows up to 40 service applications.

Presentation


1 Litre concentrate with integral dosing device.
Descaling frequency recommendation:

  • Soft / medium water areas: Every 2/3 weeks
  • Hard water areas: Use Weekly


1. Descaling the Boiling/Reservoir

  • Ensure the unit is disconnected from the power source and the boiling reservoir is empty of water
  • Add 50ml (2 x 25ml measures) of System6 concentrate together with 500ml of boiling tap water into the boiling reservoir.

Note: In situations where the boiling tank appears heavily contaminated it is
recommended to add additional boiling water/solution to fully cover the visibly soiled areas at a ratio of 500ml water to 25ml (1 measure) of System6 solution

  • Allow the solution to commence its descaling action (dependant on level of soiling this will take approximately 30 minutes)
  • Following the required contact time empty and then thoroughly rinse the boiling reservoir with fresh water in order to remove all traces of loose residue
  • In the event of gross soiling it may be necessary to repeat the above process
  • The distiller is now ready for normal use

2. Disinfecting the Distiller

  • Add 50ml (1 x 25ml measure) of System6 concentrate to approximately 500ml of boiling/hot water into the boiling reservoir
  • In order to commence disinfection of the unit set as if to allow the distiller to operate normally
  • Once the distillation process commences disconnect the distiller from its power source (DO NOT ALLOW THE UNIT TO BOIL DRY) and leave the unit to stand for a minimum 10 minute disinfection/contact time 
  • Empty and rinse out the boiling reservoir, refill with 500ml of boiling/hot water and run the distiller for approximately 10/15 minutes in order to rinse any remaining solution from within all internal/unseen parts
  • Discard all remaining water/solution and rinse the reservoir/s
  • The Distiller is now fully sanitised and ready for normal use